Portable 5.5-inch Touch Screen Patient Monitor Human/Vet/Newborn Use 6-Parameter Vital Signs Monitor

Portable 5.5-inch Touch Screen Patient Monitor Human/Vet/Newborn Use 6-Parameter Vital Signs Monitor

Veterinary use
Sale price  R 11,785.62 Regular price  R 375,951.38
Skip to product information
Portable 5.5-inch Touch Screen Patient Monitor Human/Vet/Newborn Use 6-Parameter Vital Signs Monitor

Portable 5.5-inch Touch Screen Patient Monitor Human/Vet/Newborn Use 6-Parameter Vital Signs Monitor

Sale price  R 11,785.62 Regular price  R 375,951.38
Color


Dimension and Weight

- Dimension:153*83*59mm

- Weight:0.5kg

PowerSupply

- Voltage: DC5V2A

Display

- 0.5"colorLCD

- Resolution:1280*720 pixels

Battery

- Type: Rechargeablelithiumbattery 5000 mAh3.7V

- Maximum charging time isless than6 hours.

- Working time:6 hours

Alarm

- Level: Low, mediumand high

- Indication: Auditory and visual

- Alarm volume adjustable

- Alarm pause time: 2min

Input Device

-Standard: Full Touchscreen

System Output & ExtensibleInterface

-Type-c

-WIFI


Operating Environment

-Temperature: 0〜40 。。

- Humidity:15% ~ 90%(non-condensing)

- Atmospherepressure:86 KPa ~106 KPa

Transportation and Storage -Temperature:-20〜50 。C

-Humidity:10% ~90% (non-condensing)

- Atmospherepressure:86 KPa ~106KPa

Trend &Reviewing

- NIBP measurement reviewing:1500groups

- Waveform review: 3 hours600groups

- Alarm event:1000 groups ofparameter alarmseventsand associated parameter

Respiration

- Method: Impedance between RA-LL-Gain: x0.25, x0.50, x], x2, x4

- RespirationRate: 0 ~120 /0-150BrPM

-Sweepspeed: 6.25 mm/s,12.5 mm/s,25mm/s

- Resolution:1 BrPM

- ApneaAlarm:10 ~40s

- Measure range:

-largeanimal:0-120bpm


- smallanimal:0-150 bpm

Temperature

- Technique: Thermistorprobe (2.25K /10k)

- MeasuringandAlarmRange:0.0C~50C

- Unit:Celsius(C)

-Resolution:0.1。Cor1。F

- Accuracy: ± 0.1C(exclusiveprobe)

ECG

- Leadmode: 3/5 Leads, I,II,IIIorI,II,III, AVR, AVL, AVF, V

- Gain:1/4file(X0.25)2.5 mm/mV;1/2file(X0.50) 5.0

mm/mV;1 file (X1)10 mm/mV; 2files(X2) 20mm/mV;

-Sweepspeed: 6.25mm/s,12.5mm/s, 25mm/s;

- Baseline Recovery:

< 3s after defibrillation(Monitor mode)<1s after defibrillation (Surgerymode)

- Bandwidth: Diagnostic     0.05 ~100  Monitor     0.5 ~40Hz

Surgery1 ~ 20 Hz

Heart Rate

Measure range:

- largeanimal:        15 ~ 300 bpm

- smallanimal:15 ~350bpm

- accuracy1% or1bpm, whicheverisgreater

- resolution1 bpm

SpO2

- MeasurementRange: 0~100 %

- Resolution:1%

- Response Modes: Low, Medium, High

- Accuracy: 70%~100%:2%<69%:unspecified

-Support Pitch tone and multi-level volume


Pulse Rate

- MeasuringandAlarmRange: 25~250bpm

- Accuracy:± 3 bpm

- Resolution:1bpm



NIBP

Method: Pulse wave oscillation method

Measure mode: Manual, Auto, ContinueMeasure interval inauto mode:

1,2,3,4,5,10,15,30,60,90,120,180,240,480min

-STAT mode cycle time: Keep5 minutes

- Measure and AlarmRange:

-Large Animal

-SYS     30~ 280mmHg

- DIA     10 ~220mmHg

- MEAN   20 ~240mmHg

-Small Animal

-SYS     30~220mmHg

- DIA10 ~160mmHg

- MEAN 20 ~170mmHg

- Staticpressurerange   0~300mmHg

-Static pressure accuracy 3mmHg

- Accuracy: Maximum Mean error5mmHg

- MaximumStandard deviation8mmHgStaticpressure accuracy: ±3mmHg

- Resolution:1mmHg

- Accuracy: Maximum Mean error±5mmHg

MaximumStandard deviation <8mmHg

- Over pressure Protection: large animal-300mmHg

smallanimal- 240mmHg

EtCO2 (Mainstream/ Sidestream)(Optional)

- Measure method: Non-dispersive infrared (NDIR)

- MeasureRange: 0 ~19.7%(0 ~150mmHg)0 ~20kPa

- Resolution: 0.1mmHg

- CO2Accuracy:

0 ~ 40 mmHg,±2mmHg

41 ~ 70 mmHg,±5%ofreading

71 ~100 mmHg, ±8%ofreading

101~150mmHg, ±10% ofreading

- RespiratoryRate: Range: 3~150BrPM Accuracy: ±1bpm

- RespiratoryRate: Range: 3~120BrPM Accuracy: ±1bpm

You may also like