Portable 5.5-inch Touch Screen Patient Monitor Human/Vet/Newborn Use 6-Parameter Vital Signs Monitor

Dimension and Weight
- Dimension:153*83*59mm
- Weight:0.5kg
PowerSupply
- Voltage: DC5V2A
Display
- 0.5"colorLCD
- Resolution:1280*720 pixels
Battery
- Type: Rechargeablelithiumbattery 5000 mAh3.7V
- Maximum charging time isless than6 hours.
- Working time:6 hours
Alarm
- Level: Low, mediumand high
- Indication: Auditory and visual
- Alarm volume adjustable
- Alarm pause time: 2min
Input Device
-Standard: Full Touchscreen
System Output & ExtensibleInterface
-Type-c
-WIFI
Operating Environment
-Temperature: 0〜40 。。
- Humidity:15% ~ 90%(non-condensing)
- Atmospherepressure:86 KPa ~106 KPa
Transportation and Storage -Temperature:-20〜50 。C
-Humidity:10% ~90% (non-condensing)
- Atmospherepressure:86 KPa ~106KPa
Trend &Reviewing
- NIBP measurement reviewing:1500groups
- Waveform review: 3 hours600groups
- Alarm event:1000 groups ofparameter alarmseventsand associated parameter
Respiration
- Method: Impedance between RA-LL-Gain: x0.25, x0.50, x], x2, x4
- RespirationRate: 0 ~120 /0-150BrPM
-Sweepspeed: 6.25 mm/s,12.5 mm/s,25mm/s
- Resolution:1 BrPM
- ApneaAlarm:10 ~40s
- Measure range:
-largeanimal:0-120bpm
- smallanimal:0-150 bpm
Temperature
- Technique: Thermistorprobe (2.25K /10k)
- MeasuringandAlarmRange:0.0C~50C
- Unit:Celsius(C)
-Resolution:0.1。Cor1。F
- Accuracy: ± 0.1C(exclusiveprobe)
ECG
- Leadmode: 3/5 Leads, I,II,IIIorI,II,III, AVR, AVL, AVF, V
- Gain:1/4file(X0.25)2.5 mm/mV;1/2file(X0.50) 5.0
mm/mV;1 file (X1)10 mm/mV; 2files(X2) 20mm/mV;
-Sweepspeed: 6.25mm/s,12.5mm/s, 25mm/s;
- Baseline Recovery:
< 3s after defibrillation(Monitor mode)<1s after defibrillation (Surgerymode)
- Bandwidth: Diagnostic 0.05 ~100 Monitor 0.5 ~40Hz
Surgery1 ~ 20 Hz
Heart Rate
Measure range:
- largeanimal: 15 ~ 300 bpm
- smallanimal:15 ~350bpm
- accuracy1% or1bpm, whicheverisgreater
- resolution1 bpm
SpO2
- MeasurementRange: 0~100 %
- Resolution:1%
- Response Modes: Low, Medium, High
- Accuracy: 70%~100%:2%<69%:unspecified
-Support Pitch tone and multi-level volume
Pulse Rate
- MeasuringandAlarmRange: 25~250bpm
- Accuracy:± 3 bpm
- Resolution:1bpm
NIBP
Method: Pulse wave oscillation method
Measure mode: Manual, Auto, ContinueMeasure interval inauto mode:
1,2,3,4,5,10,15,30,60,90,120,180,240,480min
-STAT mode cycle time: Keep5 minutes
- Measure and AlarmRange:
-Large Animal
-SYS 30~ 280mmHg
- DIA 10 ~220mmHg
- MEAN 20 ~240mmHg
-Small Animal
-SYS 30~220mmHg
- DIA10 ~160mmHg
- MEAN 20 ~170mmHg
- Staticpressurerange 0~300mmHg
-Static pressure accuracy 3mmHg
- Accuracy: Maximum Mean error5mmHg
- MaximumStandard deviation8mmHgStaticpressure accuracy: ±3mmHg
- Resolution:1mmHg
- Accuracy: Maximum Mean error±5mmHg
MaximumStandard deviation <8mmHg
- Over pressure Protection: large animal-300mmHg
smallanimal- 240mmHg
EtCO2 (Mainstream/ Sidestream)(Optional)
- Measure method: Non-dispersive infrared (NDIR)
- MeasureRange: 0 ~19.7%(0 ~150mmHg)0 ~20kPa
- Resolution: 0.1mmHg
- CO2Accuracy:
0 ~ 40 mmHg,±2mmHg
41 ~ 70 mmHg,±5%ofreading
71 ~100 mmHg, ±8%ofreading
101~150mmHg, ±10% ofreading
- RespiratoryRate: Range: 3~150BrPM Accuracy: ±1bpm
- RespiratoryRate: Range: 3~120BrPM Accuracy: ±1bpm